Model |
SUN-7K-SG05LP1-EU-SM2 |
SUN-7.6K-SG05LP1-EU |
SUN-8K-SG05LP1-EU-SM2 |
Battery Input Data |
|
Battery Type |
Lead-acid or Lithium-ion |
Battery Voltage Range(V) |
40-60 |
Max.Charging Current(A) |
175 |
190 |
190 |
Max.Discharging Current(A) |
175 |
190 |
190 |
Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
Number of battery input |
1 |
PV String Input Data |
|
Max. PV Access Power (W)
|
14000 |
15200 |
16000 |
Max PV Input PowerïžWïž |
11200 |
12160 |
12800 |
Max PV Input VoltageïžVïž |
500 |
Start-up VoltageïžVïž |
125 |
MPPT Voltage RangeïžVïž |
150-425 |
Rated PV Input Voltage(V) |
370 |
Max Input Short-Circuit CurrentïžAïž |
34+34 |
Max Operating PV Input CurrentïžAïž |
26+26 |
No.of MPP Trackers/No.of String Per MPP Tracker |
2/2+2 |
AC Input/Output Data |
|
Rated AC Input/Output Active PowerïžWïž |
7000 |
7600 |
8000 |
Max AC Input/Output Apparent Power ïžVAïž |
7700 |
8360 |
8800 |
Peak Power (off-grid)ïžWïž |
2 times of rated power,10s |
Rated AC Input/Output CurrentïžAïž |
31.9/30.5 |
34.5/33.1 |
36.4/34.8 |
Max AC Input/Output CurrentïžAïž |
35/33.5 |
38/36.4 |
40/38.3 |
Max Continuous AC Passthrough (grid to load)ïžAïž |
50 |
Rated Input/Output Voltage/Range(V) |
220V/230 0.85Un-1.1Un |
Grid Connection Form |
L+N+PE |
Rated Input/Output Grid Frequency/Range |
50Hz/45Hz-55Hz    60Hz/55Hz-65Hz |
Power Factor Adjustment Range |
0.8 leading-0.8lagging |
Total Current Harmonic Distortion THDi |
<3% (of nominal power)
|
DC Injection Current |
<0.5%ln |
Efficiency |
|
Max Efficiency |
97.6% |
Euro Efficiency |
96.5% |
MPPT Efficiency |
ïž99% |
Equipment Protection |
|
Integrated
|
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
|
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
Interface |
|
Communication Interface |
RS485/RS232/CAN |
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
|
Operating Temperature Range |
-40 to +60â, >45â Derating
|
Permissible Ambient Humidity |
0~100% |
Permissible Altitude |
2000m |
Noise |
ïž30Â dB(A) |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC),OVC III(AC) |
Cabinet sizeïžW*H*Dïž[mm] |
366Ã589.5Ã237 (Excluding Connectors and Brackets) |
Weight[kg] |
26.8 |
Warranty |
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
Type Of Cooling |
Intelligent air cooling |
Grid Regulation |
IEC 61727,IEC 62116,CEI 0-21,EN 50549ïžNRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |